Every fire, building, elevator, boiler, pool and workplace rule that can cite your building. What changed, when it's due, and who reviewed it. Florida, statewide to city.
Members get the full calendar with reminders at 90, 30 and 7 days, filtered to the systems on each building, and the record of who acknowledged each item.
| Area | In force | Authority | Next |
|---|---|---|---|
| Fire | Florida Fire Prevention Code, 8th Ed. (2023)NFPA 1 and NFPA 101 (2021), Florida-amended, since Dec 31, 2023. Source | State Fire Marshal; enforced by your local fire official | 9th Ed. target Dec 31, 2026 |
| Building | Florida Building Code, 8th Ed. (2023)Rule 9B-3.047. Alterations, changes of use, §510 radio coverage in existing buildings. Source | Florida Building Commission; your local building official | 9th Ed. target Dec 31, 2026 |
| Elevators | ASME A17.1-2019 · A17.3-2020Rule 61C-5.001, re-adopted May 25, 2026, under Chapter 399. Source | DBPR, Bureau of Elevator Safety | Deferred A17.3 parts Aug 1, 2028 |
| Boilers | Chapter 554, F.S. · Rule 69A-51Certificate inspections; CO detection in boiler rooms, §554.108(6). Source | State Fire Marshal (DFS), not DBPR | In force |
| Pools and spas | Rule 64E-9, F.A.C.Operational requirements 64E-9.004, amended June 11, 2023. Federal drain rules apply on top. Source | Florida Department of Health | In force |
| Public lodging | Chapter 509, F.S. · Rules 61C-1, 61C-3Balcony and railing certificate every three years, three stories or more, §509.2112. Source | DBPR, Hotels and Restaurants | In force |
| Workplace | OSHA, 29 CFR 1910Hazard Communication: substances Nov 20, 2026; mixtures May 19, 2028, per 91 FR 1695. Source | Federal OSHA (Florida is a federal-OSHA state) | Nov 20, 2026 |
| Accessibility | 2010 ADA StandardsFlorida Accessibility Code is adopted with the Building Code. Source | U.S. Department of Justice | In force |
| Miami-Dade | Building recertification, County Code §8-11First at 25 years within three miles of the coast (built 1998 or later), 30 years elsewhere, then every 10. Report due 90 days from notice. Source | County RER; city building departments inside city limits | In force |
Fire: Miami-Dade Fire Rescue, Fire Prevention Bureau, for unincorporated areas and contract cities. Cities with their own fire department, such as Miami Beach and Coral Gables, enforce the same code through their own AHJ.
Building: the county's Department of Regulatory and Economic Resources in unincorporated areas; each city's building department inside city limits. Lodging and elevators: DBPR. Boilers: the State Fire Marshal.
One address, every authority that can cite it, and a record of who saw what. Cancel anytime. Public pages stay free.
$790 a year paid up front. Alerts filtered to your systems, the calendar with reminders, full history, acknowledgment record.
One view across every address, with the same record per building.
Every jurisdiction you work in, for fire alarm, sprinkler, elevator and life-safety contractors.
The authority having jurisdiction: the fire marshal, the building official, the state licensing board, the county inspector, or a federal agency. Any organization with legal power to enforce a code against your building. Most buildings have several.
The State Fire Marshal targets December 31, 2026; the posted Florida amendments to NFPA 1 (2024) carry that date under Rule 69A-60.003. The 8th Edition (2023) is enforceable until then.
November 20, 2026 for substances (labels, written program, training) and May 19, 2028 for mixtures, per 91 FR 1695.
The Department of Financial Services, Division of State Fire Marshal, under Chapter 554 and Rule 69A-51. Not DBPR.
Buildings three stories or taller are recertified at 25 years if within three miles of the coast (built 1998 or later) or 30 years elsewhere, then every 10 years, under County Code §8-11. A Florida-licensed engineer or architect prepares the report, due 90 days from the county's notice.
No. It reports what changed, when it takes effect, and where it touches your building, with the source document and the name of the person who reviewed it. Applicability is confirmed with your AHJ or counsel.